This kit is designed to rich and extract 100bp-500bp circulating DNA from 5 ml cell-free body fluids (such asplasma, Serum), and remove fragments above 500bp. Machine reaction only takes 90 Protokoll. Magnetic-particle technology provides high-quality DNA that is suitable for direct use in downstream applications such as PCR and next generation sequencing.
Einzelheiten
Spezifikationen
Merkmale | Spezifikationen |
Hauptfunktionen | Isolation circulating DNA from 5ml plasma, Serum, body fluids |
Anwendungen | qPCR, NGS, usw. |
Reinigungstechnologie | Magnetperlen-Technologie |
Prozessmethode | Handbuch (Zentrifugation oder Vakuum) |
Beispielstyp | Serum, Plasma |
Probenmenge | 5ml |
Elutionsvolumen | ≥40μl |
Zeit pro Lauf | ≤50 minutes |
Prinzip
This product is based on the purification method of high binding magnetic particles. The sample is lysed and digested under the action of lysate and Protease. DNA is released into the lysate. Nach Zugabe von Magnetpartikeln und Bindelösung, DNA wird auf der Oberfläche magnetischer Partikel adsorbiert, und Verunreinigungen wie Proteine werden ohne Adsorption entfernt. Die adsorbierten Partikel wurden mit Waschlösung gewaschen, um Proteine und Verunreinigungen zu entfernen, mit Ethanol gewaschen, um Salze zu entfernen, and finally DNA was eluted by elution buffer.
Vorteile
- Economy – less than 50% of the price of Qiagen and other imported products
- Automatic – without labour
Inhalt des Kits
Inhalt | 1292750 | 12927200 |
Reinigungszeiten | 50 | 200 |
MagPure Particles G | 20 ml | 80 ml |
Partikel binden (selection particles) | 14 ml | 58 ml |
Selection Solution | 100 ml | 400 ml |
Proteinase K | 300 mg | 1.2 G |
Protease-Auflösungspuffer | 25 ml | 100 ml |
Puffer Sicherheitsdatenblatt(20%) | 15 ml | 60 ml |
Buffer MLK | 300 ml | 3 X 450 ml |
Puffer BST1 | 225 ml | 2X 450 ml |
Buffer MKW1 | 225 ml | 2X 450 ml |
Buffer MW2* | 50 ml | 2X 100 ml |
Puffer AE | 10 ml | 30 ml |
Lagerung und Stabilität
MagPure Particles G, MagBind Particles and Proteinase K should bestored at 2–8°C upon arrival. Jedoch, kurzfristige Lagerung (bis zu 12 Wochen) bei Raumtemperatur (15–25°C) hat keinen Einfluss auf ihre Leistung. The remaining kit components can be stored dry at roomtemperature (15–25°C) und sind mindestens stabil 18 months underthese conditions.The entire kit can be stored at 2–8°C, In diesem Fall sollten die Puffer jedoch vor der Verwendung erneut aufgelöst werden. Stellen Sie sicher, dass alle Puffer bei der Verwendung Raumtemperatur haben.
Bewertungen
Es gibt noch keine Bewertungen.