Kit de ensayo de contenido de iones de ferri en suero
Nota: Tome dos o tres muestras diferentes para predecir antes de la prueba..
Equipo de operación: espectrofotómetro
Cat Number: BC1730
Tamaño: 50T/48S
Componentes:
reactivo yo: Polvo×2, storage at 4℃. Agregar 10 mL de agua destilada antes de su uso..
Reagent Ⅱ: Polvo×2, storage at 4℃. Agregar 313 μL glacial acetic acid and 10 mL de agua destilada antes de su uso.. Standard Solution: Líquido 3 mL×1, 1000 μmol/L Fe3+ standard solution, storage at 4℃. Add distilled water dilute 8 times to form a standard solution of 125 μmol/L before use.
Descripción del Producto:
Serum iron is the iron bound with transferrin in blood, which is often used to distinguish non-iron deficiency anemia and iron-deficiency anemia.
Fe3+ is reduced by sodium sulfite to Fe2+, which reacts with 2,2-dipyridine-bipyridine, have an absorption peak at 520 Nuevo Méjico. According measure absorbance at 520 nm can reflect serum iron concentration.
Reactivos y equipos necesarios pero no suministrados.
espectrofotómetro, centrífugo, glacial acetic acid, adjusted transferpettor, 1 cubeta de vidrio de ml, chloroform and distilled water.
Procedimiento:
- Precalentar el espectrofotómetro durante 30 mín., ajustar la longitud de onda a 520 Nuevo Méjico, poner a cero con destilado
- Dilute standard solution to 125 μmol/L with distilled
- Agregue reactivos con la siguiente lista:
Nombre del reactivo (µL) | tubo en blanco (AB) | Tubo de ensayo (EN) | tubo estándar (COMO) |
Agua destilada | 400 | ||
Solucion estandar (125 μmol/L) | 400 | ||
Suero(plasma) | 400 | ||
reactivo yo | 400 | 400 | 400 |
Reactivo II | 400 | 400 | 400 |
Mezclar bien, incubate in boiling water bath for 5 mín., cooling liquid. Agregar 200 μL chloroform (required but not provided). Mezclar bien, temperatura ambiente, 10000 rpm centrifuge for 10 mín.. Llevar 700 μL supernatant to 1 cubeta de vidrio de ml. Measure absorbance at 520 Nuevo Méjico. Recorded as AB, EN, COMO. |
Cálculos
Serum iron (μmol/L)=[Cs×(AT-AB)÷(As-AB)]= 125×(AT-AB)÷(As-AB)
Cs: Fe3+ standard solution, 125 μmol/L.
Nota:
- There is less iron in the serum, so the vessels (EP tubes) should be noted to avoid iron contamination.
- Reagent I and Reagent II are unstable. It needs to be prepared when the solution will be used, and the newly prepared reagent can only be used on the same day.
- When At- Ac>5, please dilute the Serum to appropriate concentration with distilled water.
Especificaciones técnicas:
Límite mínimo de detección:3.212 µmol/mL
Rango lineal:3.9-250 µmol/mL
Productos relacionados:
BC2860/BC2865 Serum Total Iron Binding Capacity(TIBC) Kit de ensayo
BC0720/BC0725 Blood Calcium Content Assay Kit
Reseñas
Aún no hay reseñas.