説明

Notice: You need an Immunofluorescence Analyzer to run the tests with this kit

Contact us for the equipment and test kits combo wholesale


SPECIFICATION

10 Test/Box

Cat.No.:MG-CA-R012

INTENDED USE

The FHV-Ab test is a fluorescence immunoassay used along with an Immunofluorescence Analyzer for quantitative determination of panleukopenia virus antibody concentration in serum or plasma. The test can provide a reference for the level of FHV-Ab titer after vaccination of pets and suggest whether it is necessary to vaccinate them again. Another use of the test is an aid in the diagnosis and monitoring of feline panleukopenia virus infection.

For in vitro diagnostic use only. For professional use only

TEST PRINCIPLE

1. This test employs a quantitative double antigen sandwich fluorescence immunoassay technique.

2. The fluorescent signal intensity reflects the amount of FHV-Ab captured. The concentration is expressed as Tu/ml.

MATERIAL

コンテンツQuantity
Individual Sealed Pouches10
Test DevicePer pouch
Desiccant PouchPer pouch
ID Chip1
使用説明書1
FHV-Ab Sample Buffer Tubes10
Pipette Tips10

Material Required But Not Provided:

装置
Immunofluorescence Analyzer
Timer
ピペット
遠心

STORAGE AND STABILITY

  1. Store the test kit at 4~30℃ up to the expiration date.
  2. The test should operate at 18 ~ 28℃ after the Test Device opening.
  3. Once the pouch is opened, the test should be performed within 30 分.

SPECIMEN COLLECTION AND PREPARATION

The test can be performed with serum or plasma.

  1. Separate serum or plasma (EDTA anticoagulant is recommended) from blood within 3 時間 after blood collection. If a specimen appears to be severely hemolyzed, another specimen should be obtained and tested.
  1. Optimally, the test should be performed immediately after the specimen collection. If the test cannot be performed within 3 時間 after blood collection, store the specimen at 2 ~ 8℃ for no longer than 72 時間. For long-term storage, specimens shall be kept below -20℃.

Bring all materials to room temperature before use. Frozen specimens must be completely thawed and mixed well prior to testing. Specimens should not be frozen and thawed repeatedly. Only clear, non-hemolyzed specimens can be used.

TEST PROCEDURE

Refer to the Immunofluorescence Analyzer Operation Manual for complete instructions for the use of the Test device.

  1. Set a Test Device on a clean, level horizontal table.
  2. Insert the ID Chip into the meter, and clickRead ID chip”. Make sure that the Test Device lot No. matches with ID Chip No.
  1. ピペット 20 メートルof prepared sample into the FHV-Ab Sample Buffer and gently mix well. Vigorous agitation and foaming should be avoided.
  1. ピペット 100 メートルof mixed sample to add into the sample well (S) of the test device. Avoid forming bubbles.
  1. Test mode: a or b

ある) Standard Test: ClickStandard Test”, insert the Test Device into the device holder of the meter right after adding the sample to the sample well, and clickStart TestSelect sample typeSerum/Plasma”. The meter will start to countdown and read the test result automatically.

b) Quick Test: ClickQuick Test”, and start the timer right after adding the sample mixture to the sample well. Leave the Test Device at room temperature (18 ~ 28) のために 10 分. Then insert the test device immediately into the holder of the meter and clickStart Test”. Select sample typeSerum/Plasma”. The instrument will scan the Test Device automatically and show the test result.

  1. Results are displayed on the main screen, print automatically, or be printed by clickingPrint”.

QUALITY CONTROL

Each FHV-Ab Rapid Quantitative Test contains an internal control for routine quality control requirements. This internal quality control is performed each time a patient sample is tested, If an invalid result from the internal control occurs, the meter will display an error message, indicating that another test should be conducted.

INTERPRETATION

Reference range of FHV-Ab in feline serum or plasma.

  1. Detection range: 5.0 ~ 640 Tu/ml
  2. Reference range:
Item Result (Tu/ml)レベルSuggestion
100No antibody protection, vaccination recommended.
10 – 151The antibody protection is weak, so it is recommended to carry out supplementary immunization or adjust the immunization program.
15 – 452The antibody protection is weak, so it is recommended to carry out supplementary immunization or adjust the immunization program.
45 – 1003Moderate antibody protection, and strengthen antibody level monitoring, once every 6 months or so.
100 – 1504Moderate antibody protection, and strengthen antibody level monitoring, once every 6 months or so.
> 1505The antibody protection is strong, and the antibody level is tested every year to ensure vaccine protection in time.

注記: If the pet has not been vaccinated, but the test results show that the level is above level 1, it indicates that the pet may have been infected in the past.

Each laboratory should establish a reference range that is representative of the population to be evaluated.

WARNINGS AND LIMITATIONS OF THE PROCEDURE

  1. This kit is for in vitro diagnostic use only.
  2. Inspect the packaging and labels before use. Do not use it if the pouch is broken, torn, or not well sealed, or if the vial looks damaged or leaked.
  3. Do not use the test device beyond the expiration date.
  4. One pipette tip should be used for one specimen only.
  5. There is the possibility that factors such as technical or procedural errors, as well as additional substances in blood specimens that are not listed in the text, may interfere with the test and cause erroneous results.

 