Migi (猫) Feline Herpes Virus Antigen (FHV-Ag) Rapid Quantitative Test Kit

$50.00

送料USD 45 - 米ドル以上は無料 300

DTE は、分子検査のオンライン販売に特化した中国に拠点を置く電子商取引プラットフォームです, エリサ, および関連製品.

  • メーカー: 中国の一流ブランド
  • 配送: 工場から直接FedExで迅速に発送
  • 以内であれば返品または交換が可能です 30 日々
  • お支払い方法: 安全な PayPal またはクレジット カード.

説明

Notice: You need an Immunofluorescence Analyzer to run the tests with this kit

Contact us for the equipment and test kits combo wholesale


SPECIFICATION

10 Test/Box

Cat.No.:MG-CA-R007

INTENDED USE

The FHV-Ag test is a fluorescence immunoassay used along with an Immunofluorescence Analyzer for quantitative determination of herpes virus Antigen concentration in feline nasopharyngeal or ocular swabs. The test is used as an aid in the diagnosis and monitoring of feline herpes virus infection.

For in vitro diagnostic use only. For professional use only.

TEST PRINCIPLE

1. This test employs a quantitative double antibody sandwich fluorescence immunoassay technique.

2. The fluorescent signal intensity reflects the amount of FHV-Ag captured. The concentration is expressed as Tu/ml.

MATERIAL

Material ProvidedMaterial Required But Not Provided
Each box contains:
1. 10 individual sealed pouches, each containing:1. Immunofluorescence Analyzer
a Test Device2. Timer
a desiccant pouch3. ピペット
2. One ID Chip4. 遠心
3. 使用説明書
4. 10 cotton swabs
5. 10 tubes of CPV-Ag Sample Buffer
6. 10 Pipette tips

STORAGE AND STABILITY

  1. Store the test kit at 4~30℃ up to the expiration date.
  2. The test should operate at 18 ~ 28℃ after the Test Device opening.
  3. Once the pouch is opened, the test should be performed within 30 分.

SPECIMEN COLLECTION AND PREPARATION

  1. The test can be performed with a rectal swab.
  2. Collection of rectal sample: insert the swab into the rectum of the feline and rotate the swab close to the inner wall 3 ~ 5 回. The sample volume is about 1/2 ~ 2/3 cotton tip.
  3. Optimally, the test should be performed immediately after the specimen collection. If the test cannot be performed within 3 時間 after collection, store the specimen at 2~8℃ for no longer than 48 時間. For long-term storage, specimens shall be kept below -20℃.

Bring all materials to room temperature before use. Frozen specimens must be completely thawed and mixed well prior to testing. Specimens should not be frozen and thawed repeatedly. Only clear, non-hemolyzed specimens can be used.

TEST PROCEDURE

Refer to the Immunofluorescence Analyzer Operation Manual for complete instructions for use of the Test device.

  1. Set a Test Device on a clean, level horizontal table.
  2. Insert the ID Chip into the meter, and click“Read ID chip. Make sure that the Test Device lot No. matches with ID Chip No.
  3. Place the rectal swab with the sample into the FHV-Ag Sample Buffer. Stir thoroughly and 遠心分離機用 1 分 (3000 ~ 5000rpm).
  4. ピペット 100 メートルof mixed sample to add into the sample well (S) of the test device. Avoid forming bubbles.
  5. Test mode: a or b

ある) Standard Test: ClickStandard Test”, insert the Test Device into the device holder of the meter right after adding the sample to the sample well, and clickStart Test. Select sample type Rectal Swab”. The meter will start to countdown and read the test result automatically.

b) Quick Test: ClickQuick Test, and start the timer right after adding the sample mixture to the sample well. Leave the Test Device at room temperature (18 ~ 28) のために 10 分. それから insert the test device immediately insert the holder of the meter and clickStart Test”. Select sample typeRectal Swab”. The instrument will scan the Test Device automatically and show the test result.

  1. Results are displayed on the main screen, print automatically, or be printed by clickingPrint”.

QUALITY CONTROL

Each FHV-Ag Rapid Quantitative Test contains an internal control for routine quality control requirements. This internal quality control is performed each time a patient sample is tested, If an invalid result from the internal control occurs, the meter will display an error message, indicating that another test should be conducted.

INTERPRETATION

Reference range of FHV-Ag in feline rectal swab.

  1. Detection range: 4.0 ~ 640 Tu/ml
  2. Reference range:
結果 (Tu/ml)Suggestion
8Negative (-)
8 ~ 15Suspected (±)
15 ~ 40Weak Positive (+)
40 ~ 200Medium Positive (++)
> 200Strong Positive (+++)

Each laboratory should establish a reference range that is representative of the population to be evaluated.

WARNINGS AND LIMITATIONS OF THE PROCEDURE

  1. This kit is for in vitro diagnostic use only.
  2. Inspect the packaging and labels before use. Do not use it if the pouch is broken, torn, or not well sealed, or if the vial looks damaged or leaked.
  3. Do not use the test device beyond the expiration date.
  4. One pipette tip should be used for one specimen only.
  5. There is the possibility that factors such as technical or procedural errors, as well as additional substances in blood specimens that are not listed in the text, may interfere with the test and cause erroneous results.

 

レビュー (0)

レビュー

まだレビューはありません.

最初にレビューしてみませんか?Migi (猫) Feline Herpes Virus Antigen (FHV-Ag) Rapid Quantitative Test Kit

あなたのメールアドレスが公開されることはありません. 必須フィールドは、マークされています *

アタッチメント

ショッピングカート
トップにスクロールします