HiPure Circulating Nucleic Acid Micro Kit

$199.00$890.00

Shipping USD 45 - Free over USD 300

DTE is a China-based e-commerce platform specializing in online sales of molecular testing, ELISA, and related products.

  • Manufacturer: Leading Chinese brands
  • Shipping: Expedited FedEx shipping directly from the factories
  • Eligible for return or replacement within 30 days
  • Payment Methods: Secure PayPal or credit card.

Description

HiPure Circulating Nucleic Acid Micro Kit, is designed to efficiently purify short nucleic acids (<1000bp) from human biological fluids.

  • Target Molecules:
    • Tumor-derived cell-free DNA fragments (cfDNA) and mRNA in blood
    • Fetal nucleic acids in maternal blood
    • Free-circulating cell-free RNA (cfRNA)
    • Viral nucleic acids
  • Sample Compatibility:
    • Human plasma
    • Human serum
    • Human urine
    • Samples can be fresh or frozen (once only)
  • Efficient Purification: The kit isolates short nucleic acids present in biofluids.
  • High Purity: Purified nucleic acids are free of proteins, nucleases, and other contaminants.
  • Downstream Applications: The eluted nucleic acids are ready for use in various downstream analyses, including:
    • Amplification reactions (e.g., PCR)
    • Long-term storage (-30°C to -15°C)

Benefits:

  • Suitable for Short Nucleic Acids: Specifically designed to capture short fragments often found in biofluids.
  • Broad Sample Compatibility: Works effectively with various human biofluids.
  • High-Quality Results: Delivers purified nucleic acids free of impurities, ensuring reliable downstream applications.
  • Convenient Storage: Purified nucleic acids can be stored for long-term use.

This kit empowers researchers studying circulating nucleic acids in various fields, including oncology, non-invasive prenatal testing (NIPT), and viral diagnostics.

Specifications

FeaturesSpecifications
Main FunctionsIsolation circulating DNA from 0.6ml plasma, serum, body fluids
ApplicationsqPCR, liquid or solid chip analysis, hybridization, and SNP detection, etc.
Purification methodMini spin column
Purification technologySilica technology
Process methodManual (centrifugation or vacuum)
Sample typeSerum, plasma, and other cell-free fluid samples
Sample amount0.6ml
Elution volume≥30μl
Time per run≤40 minutes
Liquid carrying volume per column800μl
Binding yield of column100μg

Principle

This product offers a fast and efficient method for purifying DNA using silica column chromatography. Here’s a breakdown of the process:

1. Lysis and Digestion:

  • The sample is treated with a lysate solution and protease to break open cells and degrade proteins. This releases DNA into the solution.

2. Binding to Silica Membrane:

  • The lysate containing the DNA is transferred to an adsorption plate or filtration column. The silica membrane in these tools selectively binds DNA molecules due to favorable interactions, while proteins and other impurities pass through.

3. Washing:

  • Wash buffers are passed through the column, removing unbound proteins and cellular debris that didn’t adhere to the silica.

4. Elution:

  • A low-salt buffer is used to elute the purified DNA from the silica membrane. This disrupts the interaction between DNA and the silica, allowing collection of purified DNA in a separate tube.

This method provides a valuable tool for researchers working in various fields that require purified DNA for analysis, such as PCR, Southern blotting, and next-generation sequencing.

Advantages

  • Efficient Purification: Silica column technology offers a streamlined process for isolating DNA from complex biological samples.
  • High-Quality DNA: The selective binding properties of the silica membrane ensure the purification of high-purity DNA, suitable for various downstream applications.
  • Simplified Workflow: The protocol involves minimal handling steps and centrifugation for user-friendly and efficient extraction.

Kit Contents

ContentsD318002D318003
Purification Times50 Preps250 Preps
Buffer ACL40 ml200 ml
Buffer DCW122 ml110 ml
Buffer DCW2*20 ml2 x 50 ml
Proteinase K34 mg180 mg
Protease Dissolve Buffer1.8 ml10 ml
Carrier RNA110 μg310 μg
Nuclease Free Water10 ml30 ml
HiPure CFDNA Mini Columns50250
2 ml Collection Tubes1005 x 100

Storage and Stability

Optimal Performance:

  • Store Proteinase K and Carrier RNA at 2-8°C (refrigerator) upon arrival for best results.

Acceptable Short-Term Storage:

  • Proteinase K and Carrier RNA can be stored for up to 12 weeks at room temperature (15-25°C) without affecting their performance.

Remaining Kit Components:

  • Store all other components of the kit dry at room temperature (15-25°C).
  • They are stable for at least 18 months under these conditions.

Important Notes:

  • If storing the entire kit at 2-8°C, ensure buffers are redissolved before use.
  • Always warm all buffers to room temperature before using them for optimal performance.

By following these storage guidelines, you can ensure the longevity and effectiveness of your DNA extraction kit.

Additional information

Weight0.7 kg
SIZE

HiPure Circulating Nucleic acid Micro Kit 50 preps, HiPure Circulating Nucleic acid Micro Kit 250 preps

brand name

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “HiPure Circulating Nucleic Acid Micro Kit”

Your email address will not be published. Required fields are marked *

Attachment

Shopping Cart
Scroll to Top